Don't get caught without power with generator hire. Perfect for providing emergency power or a temporary electricity solution, generator hire allows you power where you need it for work sites or events. We work with generator suppliers UK-wide to provide you with the power source you need delivered where you need it, browse and book generator hire below.
Hire generators near you
Generator hire
Hire temporary & emergency power
Compact and portable power generators are ideal for powering small tools and machinery on-site when the work zone is remote or isolated, and access to grid power is not possible. Larger road tow and static generators are also suitable for equipment, but they are also powerful enough to run lights, heaters, and welfare units, allowing you to ensure your site is equipped with all the amenities required to provide a healthy and comfortable environment for workers.
We have a selection of diesel, petrol, and solar hybrid units available, covering a range of sizes and power outputs. All equipment is suitable as the primary power source on construction sites, festivals, and events, and they are also ideal for auxiliary or temporary use during outages or in an emergency.
Generator usage tips
Power: Look at the wattage you need or the type and number of tools and appliances you plan to use. Then, calculate whether the generator you are looking at can handle the load.
Generator Overload: Take care not to overload the generator. You can do this if you run too many powerful tools or pieces of equipment at once.
Fuel Supply: Ensure that you have enough of the necessary type of fuel to hand, so you can keep your generator running when needed, for as long as you need. You may need a fuel tank to store adequate fuel reserves.
Location: Please note that as some units feature combustion engines, you can only use them outdoors and in well-ventilated spaces. Place your generator on-site in an accessible area, where you can get to it when needed. It also needs to be close enough to the tools and equipment.
Lighting: Ensure there is suitable lighting or that you have a torch to hand so you can operate it in the dark.
Testing: Test your generator at a time when it is not needed, such as before the start of a job or before a power outage. This will allow you to become familiar with how to start and run the unit when needed.
Electric Start Charge: Some generators have an electric start function rather than a pull cord. If your equipment has an electric start, you must ensure that the start battery is kept charged up.
Prevent Large Periods of Inactivity: Fire up your equipment occasionally, even when it is not required. This will help to keep the engine running smoothly, like with a car.
Frequently Asked Questions
What size generator do I need?
How to Calculate What Size Generator You Need
Working out the right generator size comes down to three things: what equipment you need to run, how much power each item uses, and whether anything has a high starting current that temporarily spikes the load.
Step 1: List Everything You Need to Power
Write down every piece of equipment or appliance you want the generator to run at the same time. Be realistic here — you probably don't need to run every single thing simultaneously. Focus on the essentials that must stay on during a power outage or that you need on site at any given moment.
Step 2: Add Up the Running Watts (or kW)
Every electrical device has a wattage rating, usually on a label or in the manual. Add up the running wattage of everything on your list. This gives you your continuous load in watts or kilowatts.
Step 3: Convert Watts to kVA
Generators are rated in kVA (kilovolt-amperes), not kW (kilowatts). The difference is power factor. For most diesel generators the power factor is 0.8, which means:
kVA = kW ÷ 0.8
So if your total running load is 8 kW, you need a minimum of 10 kVA. Simple as that.
What is the difference between kVA and kW on a generator?
kVA is apparent power and kW is real power, and the gap between them is the power factor. Most diesel generating sets are rated at 0.8 power factor, so a 100 kVA set delivers around 80 kW of usable power. Manufacturers quote generators in kVA and equipment is usually quoted in kW, which is where most undersizing errors start.
What is the difference between standby, prime and continuous rating?
The rating tells you how long the set can run and how much overload it will accept. Standby (ESP) is for mains failure only, with limited annual running hours and no overload capability. Prime (PRP) is for extended running on a variable load. Continuous (COP) is for constant load and unlimited hours, typically off-grid or export applications. Running a standby-rated set as a prime power source will shorten its life and can invalidate the warranty.
What is the difference between Three phase and Single-Phase Generators?
Single phase power
Single phase power is generated using a single AC wave and typically has a voltage range of 220 to 250V (or 110 to 120V on a dual voltage generator). Generators designed for single phase power feature sockets with three cables: Live, Neutral, and Earth. These generators are generally small, with a capacity of up to approximately 10kW, although some single-phase generators can reach 40-50kW. They are used primarily for powering small appliances in both residential and commercial settings, or for supplying electricity to small properties.
Three phase power
In contrast, three phase power is generated using three AC waves and typically operates at a voltage range of 380 to 440V. Generators designed for three phase power have sockets with five cables: 3 x Live, Neutral, and Earth. These generators are typically larger, with capacities above 10kW, although some models are available from around 5kW. Three phase generators are mainly used to power larger appliances, especially in commercial settings, or to supply electricity to larger properties, whether residential or commercial. In some cases, even if the appliances inside a building are single phase, a three phase generator may still be necessary for larger structures such as warehouses or factories.
It is important to note that while it is possible to draw single phase power from a three phase generator, doing so would only provide 1/3 of the total power capacity. However, this is not recommended as a long-term solution due to the potential phase imbalance it can cause on the generator.
Single Phase Power:
- Produced through a single AC wave
- Voltage range of 220-250V (or 110-120V on a dual voltage generator)
- Generators have sockets with 3 cables: Live, Neutral, and Earth
- Typically small, up to around 10kW (some can go up to 40-50kW)
- Used for powering small appliances in domestic and commercial settings, or for small properties
Three Phase Power:
- Produced with three AC waves
- Voltage range of 380-440V
- Generators have sockets with 5 cables: 3 x Live, Neutral, and Earth
- Usually larger, above 10kW (some available from around 5kW)
- Mainly used for powering larger appliances in commercial settings or larger properties
- Three phase generator may be required for larger buildings, even if appliances inside are single phase
I would like to connect a generator to my house in case of mains failure. What do I need to do?
When connecting a generator to a house or building for either mains failure or direct supply, there a several key points that need to be observed.
1. Safeguarding Utility Workers: Isolating the Generator from the Mains Supply
It is vital that the generator is completely isolated from the mains supply. This ensures that it does not electrocute a utility worker trying to restore the mains supply. To achieve this, a double-pole, break-before-make, changeover switch must be installed by a qualified electrician. This should be fitted between the electricity meter and the building consumer unit. The switch connects the building to either the mains supply or to a lead which can be plugged into the generator.
2. Adapting the Generator Input: Configuring for RCD Compatibility
Most buildings now have an RCD built into the consumer unit. This is configured to operate from the mains supply with an earthed neutral, and not from a generator with a floating earth. To utilise this protection device, it is necessary to modify the generator input so that it is configured in the same way as the mains supply. This is a simple modification for a qualified electrician, involving adding a link wire from the neutral terminal to the earth terminal.
It is recommended to make this connection in the plug that is to be used to connect to the generator. This ensures that the generator is unmodified when it is disconnected from the house, and therefore remains safe. The plug should be labelled “Do not connect to mains: Neutral-Earth link fitted”. The lead between the generator and the transfer switch is not protected by the RCD, it is therefore recommended to use a steel armoured cable for this connection. A local low-impedance earth spike needs to be installed.
3. The Danger of Back Feeding: Never Plug the Generator into a Wall Socket
NEVER attempt to supply power to a building by connecting the generator to a wall socket, a hazardous practice known as back feeding. This poses an extremely dangerous risk of electrocution to utility workers and neighbors who share the same transformer. Moreover, there is a genuine danger of someone inadvertently disconnecting the live plug, leading to potentially fatal consequences. Additionally, this method bypasses built-in household circuit protection devices, further increasing the risks involved.
How noisy are generators and Which generator should I use for quietness?
Petrol frame generators can be quite noisy, Petrol inverter (Suitcase generators) are relatively quiet, diesel generators can be sound attenuated so that noise levels are reduced, however an open frame skid diesel generator can sometimes be noisy
Invertor generators, aka portable generators tend to be the quietest generators on the market, averaging between 50-70 dba. In order to determine which quiet generator is the most suitable for your application, you must firstly decide on the amount of power you require (you can use the table below to guide you). Once you have determined the appropriate wattage, you can then compare generators with the appropriate power output, against their dba to find the quietest generator for your
The difference
What hiring tools should feel like
Traditional hire companies require trade accounts, credit checks, and depot visits. We don't.
| You want to... | Elsewhere | Here |
|---|---|---|
| Book online today | Trade account required | Today's price, locked in |
| Hire as a one-off | Credit applications | Anyone welcome |
| DIY project? | "Call for quote" | Price on screen |
| Start today | 72+ hour account setup | Fast action hire |